Comparative efficacy of mosquito coils on Anopheles stephensi (Liston), Aedes aegypti (Linn.) and Culex quinquefasciatus (Say) (Diptera: Culicidae)
A study was conducted to assess the knockdown and adulticidal efficacy of d-trans allethrin (0.1%) and d-allethrin (0.2%) mosquito coils under laboratory condition against Anopheles stephensi Liston, Aedes aegypti Linn. and Culex quinquefasciatus Say. These coils provided significant knockdown activity against the tested mosquitoes. KT50 and KT95 values indicated that Ae. aegypti was more susceptible to d-trans allethrin and An. stephensi was more susceptible to d-allethrin. Cx. quinquefasciatus was less susceptible to both the coils and needed longer time to be knocked- down. Mortality and revival rates after 24 h varied between the mosquito species. The highest mortality was recorded against Ae. aegypti (68.5%) followed by Cx. quinquefasciatus (55.5%) and An. stephensi (34.5%) respectively after 24 h of exposure to the coil fumes.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]
Comparison of mineralogical properties of highland peat and peat swamp forest; Case study: Ziarat PSF and Ghaleh-ghafeh PS
In this study, we compare the mineralogical properties of two different kind of Peat and Swamp. To achieve this goal, Samples from a highland peat and a peat swamp forest in Golestan Province, have been considered. These studies were carried out using thin sections, XRF, and XRD. Quartz, muscovite, biotite, pyroxene, and Fe in forest swamp and Fe–Mn component, Quartz, aluminum and clay in high land peat are composed mainly mineral. Result shows the concentration of aluminum and quartz in highland peat swamp and the concentration of sodium, sulphur, calcium and L.O.I in peat swamp forest is more.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]
Comparisons of Self-Efficacy and Hope among Students with Learning Disabilities and without LD
This study compared self-efficacy and hopes in 30 elementary school (sixth grade) children with learning disabilities (LD) and 30 their peers without LD. An ex post facto design was used. Statistical population comprised of all students in elementary schools (sixth grade) in, harsin, Iran, during the 2012-2013 academic year. Students with learning disability were randomly selected. The students with LD had been diagnosed by Colorado Learning Difficulties Questionnaire (CLDQ). The student completed the Wechsler Memory scale, General Self-Efficacy Scale, and Children’s Hope Scale. Data were analyzed using analysis of variance. Differences were found between the groups on the self-efficacy and hope.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]
Contraindications of Batch Staining in Malaria Diagnosis and its implications on Drug and Vaccine Protective Efficacy
The primary objective was to evaluate if batch staining of malaria blood films results in false positive smears. False positive smears (>1%) may cause a serious underestimate of a drug’s or vaccine’s protective efficacy, as well as affect evaluation of diagnostics, estimates of malaria prevalence, and clinical management. Thick blood films may float from a glass slide during staining and adhere to other films if batch staining is used resulting in false positive readings. Venous blood in EDTA anticoagulant from malaria positive samples of ? 20 parasites per high power field and a true negative sample was utilized to make thick and thin smears. Two true negative smears were stained with Giemsa stain with eight positive smears in batch in Coplin jars for 10 minutes or overnight. Two control negatives were stained alone with the same batch of stain. Blinded microscopists read these slides using a rereading paradigm. Thick film loss was graded by gross appearance ranging from 0 (none) to 4+ (> ¾ loss). A total of 602 slides were evaluated in this study, of which 392 were true positives (65%) and 210 (35%) were true negatives. Of the true negatives, 110 were batch stained with true positives, and 100 were true negative controls stained alone. Of the initial readings, 11-20% were reported falsely positive. “Fishing” or cross-contamination was infrequently noted by one of the microscopists, but was uniformly present in these smears on reexamination. Of the true positive smears (high density), 1-3% were read falsely negative. On reexamination of these slides, the cause was found to be reporting of results from very poor quality smears. Thick film loss was clearly more severe for the positive slides with 10 minute versus overnight drying (means score 0.97 vs 1.97, p <0.001). This experiment confirmed that false positive smears result from cross-contamination during batch staining using methods employed today. Since low frequencies of false positive smears can adversely impact research and product development results, single slide staining should become the norm in this setting. Reporting of false negative results occurred in malaria smears with high densities of parasites. Microscopists should be trained not to report results when smear quality is not adequate.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]
Cryptographically Secure Encryption Model for RFID Credit Card
In RFID protocols, random numbers are mainly required to analyze tag answers in order to guarantee the privacy of the owner of the transponder. Our analysis looks at the feasibility of RFID tags for supporting Cryptographically Secure Pseudorandom Number Generators on their limited chip. Here we discuss about the cryptographic approach which we have used to improve the security of RFID credit card. Also we discuss about the random bit generator used in this cryptographic approach.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]
Defective neutrophil chemotaxis in generalized aggressive periodontitis patients in Indian population
Accumulation of neutrophils in the connective tissues and junctional epithelium of the periodontium is a characteristic feature of periodontal disease. The migration of neutrophils into the area may be in response to chemotactic substances elaborated directly by bacteria or by complement-derived chemotactic factors. The function of the neutrophil is thought to be clearance of infecting microorganisms and other noxious substances. It is, therefore, not surprising that a decrease in neutrophil number and function might result in more severe periodontal disease. The aim of the present study was to evaluate the chemotactic response of the neutrophils in a group of patients suffering from generalized aggressive periodontitis. Neutrophils from 10 normal subjects and 10 generalized aggressive patients were isolated from peripheral venous blood and chemotactic response was measured using casein as the chemoattractant. Of the 10 patients analyzed 5 patients showed depressed chemotaxis to casein. Elevated chemotactic responses were seen in remaining patients. Thus all patients recruited in the study showed abnormal neutrophil chemotaxis. The results obtained were not statistically significant. Based on these results it can be concluded that patients of generalized aggressive periodontitis show abnormal chemotactic response.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]
Density functional theory studies on the structure and vibrational assignments of 2-hydroxy-4-methyl-5-nitropyridine
In this study, the solid phase FT-IR and FT-Raman spectra of the 2-hydroxy-4-methyl-5-nitropyridine (HM5NP) was recorded in the range 4000–400 cm–1 and 3500–100 cm–1, respectively. Theoretical information on the optimized geometry, harmonic vibrational frequencies, Infrared and Raman intensities were obtained by means of density functional theory (DFT) using standard B3LYP/6-311++G** level. This information was used in the assignment of the various fundamentals. Comparison of the simulated spectra with the experimental spectra provides important information about the ability of the computational method to describe the vibrational modes.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]
Density Functional Theory studies on the structure and vibrational assignments of N, N-Dimethylaniline
The FT-IR and FT-Raman spectra of the N, N-Dimethylaniline (NNDMA) was recorded in the range 4000–400 cm–1 and 3500–100 cm–1, respectively. Theoretical information on the optimized geometry, harmonic vibrational frequencies, Infrared and Raman intensities were obtained by means of density functional theory (DFT) using standard B3LYP/6-311++G** level. This information was used in the assignment of the various fundamentals. Comparison of the simulated spectra with the experimental spectra provides important information about the ability of the computational method to describe the vibrational modes.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]
Design and construction of a moisture level detector for Nigerian soil conditions
This moisture level detector has two alternative power sources (3W, 11.5V solar panel and 9V battery) which supply voltages to the system and then regulated by a 7805IC voltage regulator to 5V required by a programmable hardware (microcontroller) with embedded analog digital converter (ADC). The microcontroller receives information from the probe (sensor) inserted into the soil, processes the information and displays the output on a Liquid Crystal Display (LCD) within few seconds. The moisture contents of four soil samples A, B, C and D (respectively clay soil, loamy soil, sandy soil and silt soil) obtained from different locations were determined using this detector. Samples A, B, C and D respectively showed moisture percentages of 85%, 71%, 43% and 21%. From the obtained results, sample A showed that the moisture level is above average, sample B showed that the moisture level is just average, sample C and D showed that the moisture levels are respectively below average and poor. From the obtained result, clay soil retained more water than other soil samples due to its high water holding capacity. The moisture level detector performed at an efficiency of 85%.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]
Design, Development & Analysis of Bench Vise on Rapid Prototype Machine
Traditional Rapid Prototyping (RP) is referred to as layered manufacturing free form fabrication. It is used for the physical modelling of a new product design directly from CAD data without the use of any special tooling or significant process engineering. This reduces the lead time required to produce a prototype of product. This paper is related to designing and manufacturing of modified bench vise on rapid prototyping machining process. We have designed the conventional and modified bench vise in Pro-e CAD software and manufactured it on Dimension 1200esRPT machine and analysis is carried out in ANSYS CAE software.
Please Login using your Registered Email ID and Password to download this PDF.
This article is not included in your organization's subscription.The requested content cannot be downloaded.Please contact Journal office.Click the Close button to further process.
[PDF]